| Subject : |
|
CN6000 reset the IP configuration |
| |
| Description : |
|
How to reset the IP configuration of CN6000? |
| |
| Solution : |
|
Please refer to manual page 97. To clear the login information (and return all settings to their defaults), do the following: 1. Power off the CN-6000 and remove its housing. 2. Short the jumper on the mainboard labeled J6. 3. Power on the switch. 4. When the front panel LEDs flash, power off the switch. 5. Remove the jumper cap from J6. 6. Close the housing and start the CN-6000 back up. After you start back up, you can use the default Username and Password to log in. |
| |
| Related FAQ : |
|
SN0108 - 无法被IPinstaller侦测到
|
|
[VK6000]How to use the driver of Bosch DCN series ?
|
|
CL1216的规格
|
|
CL5800 can connect to PC directly?
|
|