VE8950 / CLI command no response
 
Description : 
Switching VE8950 video source by sending RS-232 commands from VK2100,  I'm sure the commands are correct, but can not get the response from VE8950.
 
Solution : 
The VE8950 command response time is less than 500 ms. 
In order to work with VK control system, please adjust the two settings on VK:
A. Disable " automatically reconnect if no return message is received" option
B. Adjust "Delay Interval" to 0.5 second
 