SN0116 Direct HyperTerminal Connection
 
Description : 
How do I access the SN0116 via HyperTerminal Connection?
 
Solution : 
Please follow the procedures below.
- Installation
Use an Ethernet cable and RJ-45-to-Serial Adapter (ex. SA0141) to connect one of the SN0116 serial ports to a COM port on a PC.
Port 1 on the SN0116 is the default for Console Ports.
- Set up
1. On the PC, run the HyperTerminal application.
2. Set the serial communication parameters to match the SN0116’s default settings:
9600 bps, 8 Data bits, No Parity, No Stop bits.
3. Key in [Ctrl + D] after all confirmations are done and make sure the connection is online.
A login prompt for the SN0116 will appear. Key-in the Username and Password to bring up the SN0116’s main menu.
 