News
FAQ Search icon_logout FAQ View
 
Subject : 
CC2000 PDU nodes calculation
 
Description : 
I wonder how many nodes are required to add 8-port PDU to CC2000?
 
Solution : 
It depends on the way you add the PDU.
If you add PDU as Aggregate Device, it will cost 1 node.
If you add it as a Aten PDU, it spends 8 nodes.
For example, if you add PE6208AV by choosing it as an Aten PDU device,  it will spend 8 nodes like the figure below.
This CC2000 totally has 150 nodes.  After adding PE6208AV, the available nodes become 142.
You could directly control the outlet of the PE6208AV.
If you add PE6208AV as an aggregate device, 8 ports PDU will only cost 1 node,  like the figure below.
For this situation,  you could just link the website of the PE6208AV, but couldn't control the outlets on/off via CC2000.
 
Related FAQ : 
CCKM的CA認證步驟?
CS104U的熱鍵
differences between VE801/VE802 & VE812
KE 시리즈 / Planet 스위치 구성
KE6910 / KE6912 인증 잠금은 무엇이며 어떻게 설정합니까?
 

Was this information helpful? Y   N  
Any commend for this FAQ? 
Thank you for your valueable comment!!!!
 
If you need more assistance, please click the button on the right (Ask Question) and one of our experts will help you